Line 6: Line 6:
 
# '''Fab lab 120V 20A drop - four outlets on the east wall.''' (Done; waiting for panel feed to be finished)
 
# '''Fab lab 120V 20A drop - four outlets on the east wall.''' (Done; waiting for panel feed to be finished)
 
# '''120V 15A drop on west wall in between microwave and A/C.''' (Done; waiting for panel feed to be finished)
 
# '''120V 15A drop on west wall in between microwave and A/C.''' (Done; waiting for panel feed to be finished)
# Dirty room/metal room badly needs a minimum of one 120V 20A drop. Two would be even better. (One done; waiting for panel feed to be finished, two more boxes in place needing feed wire.)
+
# Dirty room/metal room badly needs a minimum of one 120V 20A drop. Two would be even better. (One done; two need wire be connected to panel.)
# At least one drop to the electronics area. (Box in place, needs feed wire)
+
# At least one drop to the electronics area. (Wire just needs to be connected to panel.)
  
 
=== Still need to plan these ===
 
=== Still need to plan these ===
 
* A high-amperage 120/240 drop in the dirty room.  50A at least; 60A would be better.
 
* A high-amperage 120/240 drop in the dirty room.  50A at least; 60A would be better.
 +
* Ian Blais would like one near the CNC area for the popcorn machine. Could be useful for the CNCs as well.
 
* Inspect load on main space light circuit and see if we can put two to four more lights on it.  (Greg and Jon discovered it's about 6½ amps, so there's room.)
 
* Inspect load on main space light circuit and see if we can put two to four more lights on it.  (Greg and Jon discovered it's about 6½ amps, so there's room.)
* Ian Blais would like one near the CNC area for the popcorn machine. Could be useful for the CNCs as well.
+
* One more light in the woodworking area. (high importance)
* One more light in the woodworking area. (badly needed)
+
* One more in the CNC area. (low importance)
* One more in the CNC area. (not as badly needed)
+
* One more over meeting area. (medium importance)
* One more over meeting area. (not as badly needed)
+
* One more in dirty room. (medium importance)
  
 
== New breaker panel (Panel 3) ==
 
== New breaker panel (Panel 3) ==
 
We put a new breaker panel in the dirty room.  It will be fed from Panel 2, and supplies 125A.  This will allow us to run more circuits, as they will be cheaper and easier.  The drawing will get some updates when I (Greg) track down the source.
 
We put a new breaker panel in the dirty room.  It will be fed from Panel 2, and supplies 125A.  This will allow us to run more circuits, as they will be cheaper and easier.  The drawing will get some updates when I (Greg) track down the source.
 
Saturday, Aug. 22, 2015, [[User: reportingsjr | Jon ]] and [[User: Greg J Arnold | Greg ]] poured blood, sweat, and tears into getting the conduit installed.  All that remains is feeding four strands of prohibitively stiff wire through eighty feet of conduit, then we'll have power!
 
  
 
=== Circuits in Panel 3 ===
 
=== Circuits in Panel 3 ===
Line 96: Line 95:
 
*The kitchen area lights are on ??
 
*The kitchen area lights are on ??
 
*The dirty room lights are on??
 
*The dirty room lights are on??
 +
 +
= Log =
 +
==== Saturday, Aug. 22, 2015 ====
 +
[[User: reportingsjr | Jon ]] and [[User: Greg J Arnold | Greg ]] poured blood, sweat, and tears into getting the conduit installed for panel 3.  All that remains is feeding four strands of prohibitively stiff wire through eighty feet of conduit, then we'll have power!
 +
==== Tuesday, Aug. 25, 2015 ====
 +
[[User: reportingsjr | Jon ]] and [[User: Greg J Arnold | Greg ]] and Andrew got three of the wires run through the conduit. Close!
 +
==== Tuesday, Sept. 1, 2015 ====
 +
 +
[[User: reportingsjr | Jon ]] and [[User: Greg J Arnold | Greg ]] and Andrew got the last wire through the conduit. Bought the wrong size lug nut for the neutral tie in for panel 2, but we got the power running temporarily until we can fix that. Jon ran wire from panel 3 to the two unfinished boxes in the dirty room and the box by the electronics area. They only need to be tied in to panel 3. The high intensity LED light was also tied in to the switch for the welding warning light.

Revision as of 04:19, 2 September 2015

We have one. This will contain a drawing of where all of our outlets are, how the are wired together, what voltage and current they can handle, and what breaker they are connected to.

Needed Upgrades

Important ones

Bold items are super critical as breakers are popping waiting for these.

  1. Fab lab 120V 20A drop - four outlets on the east wall. (Done; waiting for panel feed to be finished)
  2. 120V 15A drop on west wall in between microwave and A/C. (Done; waiting for panel feed to be finished)
  3. Dirty room/metal room badly needs a minimum of one 120V 20A drop. Two would be even better. (One done; two need wire be connected to panel.)
  4. At least one drop to the electronics area. (Wire just needs to be connected to panel.)

Still need to plan these

  • A high-amperage 120/240 drop in the dirty room. 50A at least; 60A would be better.
  • Ian Blais would like one near the CNC area for the popcorn machine. Could be useful for the CNCs as well.
  • Inspect load on main space light circuit and see if we can put two to four more lights on it. (Greg and Jon discovered it's about 6½ amps, so there's room.)
  • One more light in the woodworking area. (high importance)
  • One more in the CNC area. (low importance)
  • One more over meeting area. (medium importance)
  • One more in dirty room. (medium importance)

New breaker panel (Panel 3)

We put a new breaker panel in the dirty room. It will be fed from Panel 2, and supplies 125A. This will allow us to run more circuits, as they will be cheaper and easier. The drawing will get some updates when I (Greg) track down the source.

Circuits in Panel 3

New Laser and chiller (20A) 1 2 Single Drop to A/C on west wall (15A)
3 4 Outlet next to breaker panel (20A)
Drop into Fab Lab (20A) 5 6 Spare 20A Breaker
Spare 20A Breaker 7 8 Spare 20A Breaker
Blank 9 10 Blank
Blank 11 12 Blank
Blank 13 14 Blank
Blank 15 16 Blank
Blank 17 18 Blank
Blank 19 20 Blank
Blank 21 22 Blank
Blank 23 24 Blank

Current outlet layout

This is a very rough layout of where outlets are in the hive. The text is the circuit breaker panel (panel 1, 2, or 3) followed by the breaker that the outlet is connected to. These locations are not exact and many outlets have not been traced yet (shown by a question mark). HIVE13.floor.plan.outlets.png

Lights

  • The fab lab and lounge lights are tied in to the majority of the outlets in those room. They are on P1B19.
  • The main lights in the space I believe are on breaker 4.
  • The electronics area lights are on ??
  • The kitchen area lights are on ??
  • The dirty room lights are on??

Log

Saturday, Aug. 22, 2015

Jon and Greg poured blood, sweat, and tears into getting the conduit installed for panel 3. All that remains is feeding four strands of prohibitively stiff wire through eighty feet of conduit, then we'll have power!

Tuesday, Aug. 25, 2015

Jon and Greg and Andrew got three of the wires run through the conduit. Close!

Tuesday, Sept. 1, 2015

Jon and Greg and Andrew got the last wire through the conduit. Bought the wrong size lug nut for the neutral tie in for panel 2, but we got the power running temporarily until we can fix that. Jon ran wire from panel 3 to the two unfinished boxes in the dirty room and the box by the electronics area. They only need to be tied in to panel 3. The high intensity LED light was also tied in to the switch for the welding warning light.